Control System 21Service Manual – SC2000
Maintenance and Adjustments
Function Electronic Board (EB1) Alarm Codes
The function electronic board indicates a series of alarms in case of malfunction of one or more systems, and
in case of abnormal conditions detected in the input signals.
The alarms are shown on the display in the following format: ALARM <XX> <DESCRIPTION> (Figure 4).
max.2%
1s
DESCRIPTION
Figure 4
In case the display is malfunctioning, the alarms are also repeated by the yellow and red diagnostic LEDs
(Figure 5) on the function electronic board (EB1), as indicated in the following tables.
Figure 5
General alarms
Alarm on function electronic board - FLASHING YELLOW + RED LEDS
Alarm code
--------------------------
Description
No.
Flashes
Meaning Condition Effect
Service Suggestions
G2
-----------------------
EEPROM
ERROR
2 EEPROM error EEPROM error Function block
+ Default setting
reset
If the machine continues to function after
G2 has been displayed, this may have
been caused by a signicant external
electromagnetic disturbance.
1. Check that the settings and parameters
(see page 29) are correct (they may
have returned to their defaults). If
the error persists, the board must be
replaced.

Table of Contents

Other manuals for Nilfisk-Advance SC2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SC2000 and is the answer not in the manual?

Nilfisk-Advance SC2000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSC2000
CategoryFloor Machine
LanguageEnglish

Related product manuals