Vacuum System Motor Amperage Test
Warning! Thisproceduremustbeperformedbyqualiedpersonnelonly.
12. Lift the recovery tank assembly and the driver’s seat.
13. Apply the amp clamp (A) to a cable (B) near the vacuum unit (Figure 5).
14. Insert the operator key in its slot.
15. Activate the vacuum by pressing the vacuum button .
16. Check that the vacuum system motor amperage is between 13 and 17A at 24V.
17. If the amperage is higher, remove the vacuum system motor (see the procedure in the Vacuum System
Motor Disassembly/Assembly paragraph), and check the condition of all its components to detect and
correct the abnormal amperage:
If the above-mentioned procedures do not produce the correct readings for the vacuum system motor
amperage, the motor must be replaced.