Solution System 97Service Manual – SC3000
Solution lter cleaning
1. Drive the machine on a level oor.
2. Turn the ignition key to “0”.
3. Close the solution valve (A) under the machine, behind the right rear wheel. The valve (A) is closed
when it is in the position (B) and it is open when it is in the position (C).
4. Remove the transparent cup (D), recover the gasket (E), then remove the lter strainer (F) under the
machine, in front of the right rear wheel. Clean them with water and install them on the support (G).
Note: Thelterstrainer(F)mustbecorrectlypositionedonthehousingofthesupport(G).
5. Open the valve (A).
D
E
F
H
G
B
C
A
P100578