Peripheral Displays and Printers System Overview
NFS-640 Installation Manual P/N 51332:B1 12/01/2003 23
Annunciator Fixed Module - AFM-32A. Contains 32 red alarm LEDs, a system trouble LED,
an ON LINE/POWER LED, and a local panel sounder with a silence/acknowledge switch. The
AFM-32A is fixed at address 1, and will not accept expander modules.
2.9 Peripheral Displays and Printers
The control panel is compatible with the following printers and display devices:
•PRN-5 Printer
Keltron Remote Printer VS4095
CRT-2 Display Terminal
All EIA-232 devices must be located in the same room within 50 feet (15.24 m) of the control
panel.
Printer - PRN-5. The PRN-5 is an optional printer that connects directly to the control panel
through an EIA-232 interface (TB14) and can be located up to 50 feet (15.24 m) from the control
panel. It creates a printed record (80 columns of data on standard 9" x 11" tractor-feed paper) of all
system events (alarm, trouble) and status changes within the system. The printout is time-stamped
with the current time-of-day and date.
Keltron Remote Printer. The VS4095 is a two-color (red/black), 40-column, 24 VDC printer
that can print 50 messages in 90 seconds. This printer connects to the control panel through an EIA-
232 interface (TB14) and mounts in a separate cabinet next to the control panel. The VS4095 meets
UL fire and security requirements for an ancillary device.
For more information, contact the manufacturer (Keltron Corp., Waltham, MA)
Display Terminal - CRT-2. This optional display terminal connects to the control panel through
an EIA-232 interface (TB15). The terminal can control and view events, points and history reports,
control the system (Acknowledge, Alarm Silence, and System Reset). The terminal displays 26
lines by 80 columns and can be located up to 50 feet (15.24 m) from the control panel within the
same room.
Note: The CRT cannot be connected at the same time as the network.

Table of Contents

Other manuals for Notifier NFS-640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier NFS-640 and is the answer not in the manual?

Notifier NFS-640 Specifications

General IconGeneral
BrandNotifier
ModelNFS-640
CategoryFire Alarms
LanguageEnglish

Related product manuals