Front Fan Module Replacement
DGX-2 System DU-09224-001 _v09|4
There are two fans in the fan module, identified by FANn_F or FANn_R , where n is the
module ID. If either fan fails, then the entire module must be replaced.
3. Use NVSM to confirm the fan issue.
$ sudo nvsm show health
In the output, look for the 'unhealthy' status for the same fan.
2.3. Replacing and Returning the Front
Fan Module
1. Remove the new fan module from its packaging and be ready to install it.
2. Locate the failed fan module on the physical system using the following diagram.