A - 39
A Appendices
E5@C Digital Temperature Controllers User’s Manual (H174)
A-6 Parameter Operation Lists
A
A-6-9 Initialization According to Parameter Changes
The parameters that are initialized when parameters are changed are shown under Related initialized
parameters.
A-6-9 Initialization According to Parameter Changes
Input Type
Temperature Unit
Scaling Lower Limit
Scaling Upper Limit
SP Lower Limit
SP Upper Limit
PID ON/OFF
Standard or
Heating/Cooling
Program Pattern
ST
Remote SP Enable
Transfer Output Type
Control Output 1 Assignment
RT
Integral/Derivative Time Unit
Alarm 1 to 4 Type
SP 0 to 7
Set Point
Password to Move to
Protect Level
Close/Floating
Direct Setting of Position
Proportional MV
Related parameter
initialization execution
condition
Temperature
input
Analog
input
*9
Position
-proport
ional
Model
with FB
input
Position
-proport
ional
Model
with FB
input,
close
control
SP Upper Limit
SP Lower Limit
*1
*1
*23
*1
--- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Set Point
*2
*2
*23
*2
*2
--- --- --- --- --- --- --- --- --- ---
*16
--- --- ---
SP0 to SP7
*2
*2
*23
*2
*2
--- --- --- --- --- --- --- --- --- ---
*16
--- --- ---
PV Input Shift
---
*23
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
RT
*3
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Proportional Band
*13
*23
--- --- --- --- --- --- --- --- ---
*9
*19
--- --- --- --- ---
Integral Time
*13
--- --- --- --- --- --- --- --- --- ---
*9
*19
--- --- ---
*21
---
Derivative Time
*13
--- --- --- --- --- --- --- --- --- ---
*9
*19
--- --- --- --- ---
Proportional Band
(Cooling)
*13
*23
--- --- --- --- --- --- --- --- ---
*9
*19
--- --- --- --- ---
Integral Time (Cooling)
*13
--- --- --- --- --- --- --- --- --- ---
*9
*19
--- --- --- --- ---
Derivative Time
(Cooling)
*13
--- --- --- --- --- --- --- --- --- ---
*9
*19
--- --- --- --- ---
Integral/Derivative
Time Unit
--- --- --- --- --- --- --- --- --- --- ---
*9
--- --- --- --- ---
MV Upper Limit, MV
Lower Limit
--- --- --- --- ---
*5
--- --- --- --- --- --- --- --- --- --- --- ---
MV at Stop
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ●●
MV at PV Error
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ●●
Manual MV
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ●●
Transfer Output Upper
Limit, Transfer Output
Lower Limit
*4
*4.1
*4.1
*4.1
*4.1
---
*4.2
--- --- ---
*4.3
--- --- --- --- --- --- --- ---
SP Mode
*17
--- --- ---
*17
*17
---
*11
*12
--- --- --- --- --- --- --- --- ---
Remote SP Enable
*17
--- --- ---
*17
*17
---
*11
--- --- --- --- --- --- --- --- --- ---
Remote SP Upper
Limit
Remote SP Lower
Limit
*1
*1
*1
--- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Control Output 1
Assignment
--- --- --- --- --- ●●--- --- --- --- --- --- --- --- --- --- ---
Control Output 2
Assignment
--- --- --- --- ---
*6
*6
--- --- --- --- --- --- --- --- --- --- ---
Auxiliary Output 1
Assignment
--- --- --- --- ---
*7
*7
--- --- --- --- --- --- --- --- --- --- ---
Auxiliary Output 2
Assignment
--- --- --- --- ---
*6
*6
--- --- --- --- --- --- --- --- --- --- ---
Related
initialized
parameters
Changed
parameter

Table of Contents

Other manuals for Omron E5CC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5CC and is the answer not in the manual?

Omron E5CC Specifications

General IconGeneral
BrandOmron
ModelE5CC
CategoryTemperature Controller
LanguageEnglish

Related product manuals