175
Appendix A
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
a-m
P
m-sp
0
P
25
C
25
0
C
sp-m
0
C
ct1
0.0
P
lcr1
0.0
P
r-s
run
P
al-1
0
C
al1h
0
C
al1l
0
C
al-2
0
C
al2h
0
C
al2l
0
C
al-3
0
C
al3h
0
C
al3l
0
C
o
0.0
P
c-o
0.0
P
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
cmwt
off
ct1
0.0
P
at
off
P
lcr1
0.0
P
hb1
0.0
P
hs1
50.0
P
sp-0
0
C
sp-1
0
C
sp-2
0
C
sp-3
0
C
ins
0.0
C
insh
0.0
C
p
8.0
C
i
233
P
d
40
P
c-sc
1.00
P
c-db
0.0
C
of-r
50.0
P
hys
1.0
C
chys
1.0
C
sprt
off
C
ol-h
105.0
P
ol-l
-5.0
P
M
M
M
M
M
M
M
psel
cwf
u-no
1
bps
9.6
len
7
sbit
2
prty
even
sdwt
20
M
M
M
oapt
0
P
icpt
1
P
wtpt
off
P
25
C
M
insl
0.0
C
Power ON
Starting in manual mode.
Manual control level
PID control
only
PV/MV
Press the
O Key for
at least 1 s
Press the O Key for at
least 3 s. Displays other than
that for switching between
automatic and manual.
Adjustment Level
Press the O Key less than 1 s.
Press the O Key less than 1 s.
Operation Level
AT Execute/Cancel
Communications Writing
Heater Current 1 Value
Monitor
Leakage Current 1
Monitor
HS Alarm 1
Heater Burnout Detection 1
SP 0
SP 3
SP 2
SP1
SP Used By
Multi-SP
Temperature Input Shift
1-Point Shift
Set either of these parameters.
Upper-Limit Temperature
Input Shift Value
2-Point Shift
Lower-Limit Temperature
Input Shift Value
Proportional Band
Integral Time
PID Settings
Derivative Time
Cooling Coefficient
Heating/Cooli
ng
Dead Band
Manual Reset Value
Clear
the Offset During Stabil-
ization of P or PD Control.
Hysteresis (Heating)
Hysteresis
Settings
Hysteresis (Cooling)
SP Ramp Set Value
MV Upper Limit
MV Lower Limit
Process Value
Added When Additional
PV Display is ON.
Auto/Manual Switch
PID Control Only.
Added When Auto/Manual
Select Addition is ON.
Press the
O Key for
at least 3 s.
Multi-SP
Set Point Setting
Heater Current 1
Value Monitor
Leakage Current 1
Monitor
RUN/STOP
Alarm Value 1
Set either of these parameters.Set either of these parameters. Set either of these parameters.
Alarm Value
Upper Limit 1
Alarm Value
Lower Limit 1
Alarm Value 2
Alarm Value
Upper Limit 2
Alarm Value
Lower Limit 2
Alarm Value 3
Alarm Value
Upper Limit 3
Alarm Value
Lower Limit 3
MV Monitor
(Heating)
MV Monitor
(Cooling)
Press the O and M Keys for at
least 3 s. Display flashess.
Press the O and M Keys
for at least 1 s.
Press the O Key
less than 1 s
Protect Level Communications Setting Level
The time taken to move to the protect level can be
adjusted by changing the "Move to protect level
time" setting.
Starting in automatic
mode.
Process value/
set point
Displayed only for models with communications.
Changes are effective after cycling power or
after a software reset.
Operation/Adjustment Protect
Restricts Displaying And
Modifying Menus In Operation,
Adjustment, And Manual
Control Levels.
Initial Setting/Communications
Protect
This Protect Level Restricts
Movement To The Initial Setting,
Communications Setting, And
Advanced Function Setting
Levels.
Setting Change Protect
Protects Changes To Setups By
Operating The Front Panel Keys.
Protocol Setting
Switches Between CompoWay/F
(SYSWAY) And Modbus.
Communications Unit No.
Communications Baud Rate
CompoWay/F
(SYSWAY) Only
Communications Stop Bits
Communications Parity
Send Data Wait Time
Set Point During SP
Ramp
Communications
Data Length
Parameter Flow
This section describes the parameters set in each
level. Pressing the M key at the last parameter in
each level returns to the top parameter in that level.

Table of Contents

Other manuals for Omron E5CZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5CZ and is the answer not in the manual?

Omron E5CZ Specifications

General IconGeneral
BrandOmron
ModelE5CZ
CategoryTemperature Controller
LanguageEnglish

Related product manuals