15
Motor Care
Protect from heat
1. Shade the motor from the sun.
2. Any enclosure must be well ventilated to prevent
overheating.
3. Provide ample cross ventilation.
Protect against dirt
1. Protect from any foreign matter.
2. Do not store (or spill) chemicals on or near the
motor.
3. Avoid sweeping or stirring up dust near the motor
while it is operating.
4. If the motor has been damaged by dirt it may void
the motor warranty.
5. Clean the lid, O-Ring, and sealing surface of the
strainer pot regularly.
Protect against moisture
1. Protect from splashing or sprayed water.
2. Protect from extreme weather.
3. If motor internals have become wet - let them dry
before operating. Do not allow the pump to operate if
it has been ooded.
4. If the motor has been damaged by water it may void
the motor warranty.
SERVICING
Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious
injury to service people, users or others due to electric shock. Read all servicing instructions before servicing the pump.
DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in
these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause
serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature
is cool to touch, then open with extreme caution.
Pump Disassembly
TOOLS REQUIRED:
1/4" socket or open-end wrench
3/8" socket or open-end wrench
9/16" open-end wrench
1/4" hex key
Flat blade screwdriver
TO DISASSEMBLE THE PUMP:
1. Press Start/Stop to stop the pump and disconnect
all power to the pump at the circuit breaker.
2. Disconnect any digital inputs or communication
cables from the pump (if connected).
3. Close all valves in suction and discharge pipes and
relieve all pressure from the system.
4. Remove both drain plugs from the bottom of the
strainer pot.
5. Using a 9/16" wrench, remove the four (4) bolts
and washers securing the strainer pot to the motor
assembly.
6. GENTLY separate the pump halves.
7. Remove the three (3) screws securing the di󰀨user to
the seal plate.
8. While holding the motor shaft in place at the rear of
the motor, remove the impeller screw.
Note: The impeller screw is reverse thread and
loosens clockwise.
9. Continue to hold the motor shaft in place and
unthread the impeller counter-clockwise.
10. Using a 9/16" wrench, remove the four (4) bolts
securing the seal plate to the motor.
11. If replacing the shaft seal, continue to Shaft Seal
Replacement on page 16.
Otherwise, continue to Pump Reassembly when
necessary.
- ILLUSTRATED PARTS VIEW ON THE NEXT PAGE -

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair SUPERFLO VST and is the answer not in the manual?

Pentair SUPERFLO VST Specifications

General IconGeneral
BrandPentair
ModelSUPERFLO VST
CategoryWater Pump
LanguageEnglish

Related product manuals