Care and maintenance
10 - 5
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
Fig. 10 - 06
Fig. 10 - 07
2
1
max.
1
2
10.06 Checking/regulating the air pressure
10.07 Emptying/cleaning the water bowl of the air filter/regulator
Switch off the machine.
Disconnect the air hose at the
air filter/regulating unit.
Emptying the water bowl
● Water bowl 1 empties itself automatically
when the air hose is disconnected from
the air filter/regulator.
Cleaning the filter
● Unscrew water bowl 1 and take out filter 2.
● Clean the filter with compressed air or
with isopropyl-alcohol, part number
95-665735-91.
● Screw in filter 2 and screw on water bowl 1.
● Check the air pressure on gauge 1 every
time before operation.
● Gauge 1 must show a pressure of 6 bar.
● Regulate this pressure if required.
To do so, pull knob 2 up and turn it
accordingly.