WITH SERVICE KEYS
Deterring blink
Switching from «ON» to «OFF» with programmed
system causes the intermittent switching on of the
LED, with an antitheft effect.
This occurs with any key used for programming.
If the scooter is not used, the deterrent light stops automatically after 48 hours to prevent discharging
the battery. A new 48-h cycle starts by switching from "OFF" to "ON" and "OFF" again.
Checking master-box data
Connect the diagnostic tester.
Set to «ON» and select the immobilizer function.
Scroll the pages the find the data.
Specific tooling
020680Y Diagnosis Tool
The information will be as follows:
- Unprogrammed control unit «OFF»
- Start-up disabled «OFF»
- Number of keys 2*
*The number denotes how many keys have been used for programming, master key included.
Resetting the circuit
1 Replacing the small cylinder
Beverly 500 i.e. Injection
INJEC - 219