NB-IoT Module Series
BC95 AT Commands Manual
BC95_AT_Commands_Manual Confidential / Released 19 / 58
OK
Neul Hi2110 Implementation
Unsolicited notifications are not currently supported. This functionality will be added in a future
release.
Only <n>=0 and <n>=1 are supported. <n>=0 is the default value.
3.7. AT+CLAC List Available Commands
This command lists the available AT commands. Execution command causes the MT to return one or
more lines of AT commands. Refer to Chapter 6 for possible <err> values. Please note that this command
only returns the AT commands that are available for the user.
Parameter
Example
AT+CLAC
AT+GM
AT+GMI
...
AT+GSN
AT+CLAC
OK
AT+CLAC List Available Commands
Execute Command
AT+CLAC
Response
<AT Command>
[<CR><LF><AT Command>[...]]
OK
+CME ERROR: <err>
AT+CLAC=?
Response
OK
<AT Command> Defines the AT command including the prefix AT. Text shall not contain the
sequence 0<CR> or OK<CR>