BC95 AT Commands Manual
BC95_AT_Commands_Manual Confidential / Released 27 / 58
has the read form in addition to the execution/set and test forms.
Neul Hi2110 Implementation
When <state>=1, +COPS=0 is automatically selected.
If a CGATT command is in progress, further execution of the CGATT command will return an Uplink
busy error.
3.12. AT+CIMI Request International Mobile Subscriber Identity
This command returns International Mobile Subscriber Identity (string without double quotes).
Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify the
individual SIM card or active application in the UICC (GSM or USIM) which is attached to MT.
Refer to Chapter 6 for possible <err> values.
Parameter
Example
AT+CIMI
460001357924680
OK
AT+CIMI Request International Mobile Subscriber Identity
Execute Command
AT+CIMI
Response
<IMSI>
OK
+CME ERROR: <err>
Test Command
AT+CIMI=?
Response
OK
<IMSI> International Mobile Subscriber Identity (string without double quotes)
<err> TBD
Quectel
Confidential

Table of Contents

Other manuals for Quectel BC95

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel BC95 and is the answer not in the manual?

Quectel BC95 Specifications

General IconGeneral
BrandQuectel
ModelBC95
CategoryControl Unit
LanguageEnglish

Related product manuals