EasyManuals Logo
Home>Quectel>Control Unit>BC95

Quectel BC95 User Manual

Quectel BC95
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
NB-IoT Module Series
BC95 AT Commands Manual
BC95_AT_Commands_Manual Confidential / Released 34 / 58
Neul Hi2110 Implementation
Only <fun>=0&1 are supported.
<rst> is not supported and will be ignored.
3.15. AT+CMEE Report Mobile Termination Error
Set command disables or enables the use of final result code +CME ERROR: <err> as an indication of an
error relating to the functionality of the MT. When enabled, MT related errors cause +CME ERROR: <err>
final result code instead of the regular ERROE final result code. ERROR is returned normally when error
is related to syntax, invalid parameters or TA functionality.
Read command returns the current setting of <n>.
Test command returns values supported as a compound value.
Refer to Chapter 6 for possible <err> values.
Parameter
Neul Hi2110 Implementation
Only <n>=0 & <n>=1 are supported.
AT+CMEE Report Mobile Termination Error
Set Command
AT+CMEE=<n>
Response
OK
Read Command
AT+CMEE?
Response
+CMEE:<n>
OK
Test Command
AT+CMEE=?
Response
+CMEE:(list of supported<n>s)
OK
<n> Integer type
0 Disable +CMEE ERROR: <err> result code and use ERROR instead
1 Enable +CMEE ERROR: <err> result code and use numeric <err> values (Refer
to Chapter 6 for possible <err> values)
2 Enable +CMEE ERROR: <err> result code and use verbose <err> values
Quectel
Confidential

Table of Contents

Other manuals for Quectel BC95

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel BC95 and is the answer not in the manual?

Quectel BC95 Specifications

General IconGeneral
BrandQuectel
ModelBC95
CategoryControl Unit
LanguageEnglish

Related product manuals