NB-IoT  Module  Series 
  BC95  AT  Commands  Manual 
 
BC95_AT_Commands_Manual                   Confidential / Released                    52 / 58 
 
 
 
5 Temporary  Commands   
 
As  part  of  development,  some  commands  are  temporarily  added.  They  are  unsupported  and  may 
disappear, or change behaviour, without warning. They are listed here for completeness. 
 
5.1. AT+NTSETID    Set ID   
 
Set system identities such as UUID or IMEI value. This is a temporary command that will be replaced with 
a production tool.   
Parameter 
Example 
AT+NTSETID=1,123456789012345 
OK 
Neul Hi2110 Implementation 
  IMEI is persistent. 
  SVN is not persistent and will default to 0x00. 
  IMEI can only be set when the radio is inactive (AT+CFUN=0 will force the module to enter into this 
state). 
 
Set Command 
AT+NTSETID=<snt>,<data> 
Response 
OK 
 
+CME ERROR: <err> 
<snt>      Integer type indicating the serial number type that has been requested 
      1      Set the IMEI   
      2      SVN 
<data>    If <snt>=1      IMEI      15-character string type in decimal format 
      If <snt>=2      SVN      2 digit SVN