EasyManuals Logo
Home>Quectel>Control Unit>MC60 Series

Quectel MC60 Series User Manual

Quectel MC60 Series
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
GSM/GPRS/GNSS Module Series
MC60 Series Hardware Design
MC60_Series_Hardware_Design Confidential / Released 47 / 114
The power down procedure causes the module to log off from the network and allows the firmware to
save important data before completely disconnecting the power supply.
Before the completion of the power down procedure, the module sends out the result code shown below:
NORMAL POWER DOWN
1. When unsolicited result codes do not appear when autobauding is active and DTE & DCE are not
correctly synchronized after start-up, the module is recommended to be set to a fixed baud rate.
2. As network logout time is related to the local mobile network, it is recommended to delay about 12
seconds before disconnecting the power supply or restarting the module.
After that moment, no further AT commands can be executed. Then the module enters the power down
mode.
VBAT
PWRKEY
(INPUT)
VDD_EXT
(OUTPUT)
0.7s<Pulldown<1s
GNSS_VCC_EN
GNSS_VCC
RUNNING
OFFGSM PART STATUS
RUNNINGGNSS PART STATUS
OFF
Log out from network in
2~12s
Figure 19: Turn-off Timing by Using the PWRKEY Pin
NOTES
Quectel
Confidential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel MC60 Series and is the answer not in the manual?

Quectel MC60 Series Specifications

General IconGeneral
BrandQuectel
ModelMC60 Series
CategoryControl Unit
LanguageEnglish

Related product manuals