Remote Control
R&S
®
FPC
306User Manual 1178.4130.02 ─ 07
Return values:
<FrequencyError> <numeric value>
Default unit: Hz
Example: //Query carrier frequency offset
CALC:MARK:FUNC:ADEM:FERR?
Usage: Query only
CALCulate<n>:MARKer:FUNCtion:ADEMod:FM[:RESult]? <MeasType>
This command queries the modulation characteristics of an FM signal.
Prerequisites for this command
●
Measure an FM signal (CALCulate<n>:FEED).
Suffix:
<n>
.
irrelevant
Query parameters:
<MeasType> MIDDle
Queries the average frequency deviation.
MPEak
Queries the minimum frequency deviation.
PPEak
Queries the maximum frequency deviation.
RMS
Queries the RMS value of the frequency deviation.
Return values:
<Result> Default unit: Hz
Example: //Query average frequency deviation
CALC:FEED 'XTIM:FMS'
CALC:MARK:FUNC:ADEM:FM? MIDD
Usage: Query only
CALCulate<n>:MARKer:FUNCtion:ADEMod:MINDex[:RESult]?
This command queries the modulation index.
Prerequisites for this command
●
Measure an AM signal (CALCulate<n>:FEED).
Suffix:
<n>
.
irrelevant
Return values:
<ModIndex> <numeric value>
Default unit: PCT
Remote Commands of the Analog Demodulation