P/N 016-5032-114 Rev. A 3
IMPORTANT SAFETY INFORMATION
1
Allow sufficient clearance from machine component operational zones such as:
Drive shafts, universal joints and hitches (i.e. 3-point hitch)
Pulleys, gears, sprockets
Deflection and backlash of belts and chains
Adjustment zones of adjustable brackets
Changes of position in RS1 HDU and suspension systems
Moving linkages, cylinders, articulation joints, attachments
Ground engaging components
For hose sections that move during machine operation:
Allow sufficient length for free movement without interference to prevent: pulling, pinching, catching or
rubbing, especially in articulation and pivot points
Clamp hoses securely to force controlled movement to occur in the desired hose section
Avoid sharp twisting or flexing of hoses in short distances
Protect hoses from:
Foreign objects such as rocks that may fall or be thrown by the unit
Buildup of dirt, mud, snow, ice, submersion in water and oil
Tree limbs, brush and debris
Damage where service personnel or operators might step or use as a grab bar
Damage when passing through metal structures
High pressure wash
ELECTRICAL
GENERAL
Always verify that the power leads are connected to the correct polarity as marked. Reversing the power leads
could cause severe damage to the equipment.
Ensure that the power cable is the last cable to be connected.
A minimum of 12 VDC is required for system operation with a maximum of 15 VDC.
INSTRUCTIONS FOR WIRE ROUTING
The word “harness” is used to mean all electrical leads and cables, bundled and unbundled. When installing
harness, secure it at least every 30 cm (12in) to the frame. Follow existing harness as much as possible and use
these guidelines:
Harness should not contact or be attached to:
Lines and hoses with high vibration forces or pressure spikes
Lines and hoses carrying hot fluids beyond harness component specifications
Avoid contact with any sharp edge or abrading surfaces such as, but not limited to:
Sheared or flame cut edges
Edges of machined surfaces
Fastener threads or cap screw heads