RIGOL Chapter 2 Command System
2-172 MSO1000Z/DS1000Z Programming Guide
:TRIGger:SLOPe:BLEVel
Syntax
:TRIGger:SLOPe:BLEVel <level>
:TRIGger:SLOPe:BLEVel?
Description
Set or query the lower limit of the trigger level in slope trigger. The unit is the same as the
current amplitude unit.
Parameter
Name
Type
Range
Default
<level>
Real
(-5 x VerticalScale - OFFSet) to
(5 x VerticalScale - OFFSet)
0
Explanation
For VerticalScale, refer to :CHANnel<n>:SCALe. For OFFSet, refer
to :CHANnel<n>:OFFSet.
Return
Format
The query returns the lower limit of the trigger level in scientific notation.
Example
:TRIGger:SLOPe:BLEVel 0.16 /*Set the lower limit of the trigger level to 160mV*/
:TRIGger:SLOPe:BLEVel? /*The query returns 1.600000e-01*/
Related
Command
:TRIGger:SLOPe:ALEVel

Table of Contents

Other manuals for Rigol DS1104Z-S Plus

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1104Z-S Plus and is the answer not in the manual?

Rigol DS1104Z-S Plus Specifications

General IconGeneral
Bandwidth100 MHz
Sample Rate1 GSa/s
Channels4
Memory Depth24 Mpts
Vertical Resolution8 bits
Vertical Sensitivity1 mV/div to 10 V/div
Timebase Range2 ns/div to 1000 s/div
Waveform RecordUp to 60, 000 frames
FFTYes
Waveform Capture Rate30, 000 wfms/s
Display7-inch TFT LCD
Trigger ModesEdge, Pulse, Video, Window, Timeout
InterfacesUSB, LAN
Serial Bus Triggering and DecodingI2C, SPI, UART
Input Impedance1 MΩ
Power Supply100-240 VAC, 45-440 Hz