RIGOL Chapter 2 Command System
2-184 MSO1000Z/DS1000Z Programming Guide
:TRIGger:TIMeout:TIMe
Syntax
:TRIGger:TIMeout:TIMe <NR3>
:TRIGger:TIMeout:TIMe?
Description
Set or query the timeout time in timeout trigger. The default unit is s.
Parameter
Name
Type
Range
Default
<NR3>
Real
16ns to 10s
16ns
Return
Format
The query returns the timeout time in scientific notation.
Example
:TRIGger:TIMeout:TIMe 0.002 /*Set the timeout time to 2ms*/
:TRIGger:TIMeout:TIMe? /*The query returns 2.000000e-03*/