EasyManuals Logo
Home>Samson>Control Unit>2417 Series

Samson 2417 Series User Manual

Samson 2417 Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
EB 2517 EN 43
Servicing
7.5 Tightening torques
Î RefertoFig.3
Component
Width across
ats
Valve size/actuator area
Tightening
torque inNm
Nut (7.2) SW30 DN15to100 10
Cap screw (7.3) 3mm DN15to100 5
Nuts for pillars (8.2) SW24 DN15to100 60
Fastening nuts (9) SW16 DN15to100 25
Control line connection (11) 40to640cm² 22
Diaphragm plate nut (14) SW12 40to640cm² 40
Nuts and bolts (15) 40to640cm² 25
7.6 Lubricants and sealants
SAMSON's After-sales Service department
can support you concerning lubricants and
sealants approved by SAMSON.
7.7 Accessories
Table8: Assignment of compensation
chamber (18) to regulator, with item no.
Type2413 Actuator
Actuator area A
Item number
∙Compensation
chamber
DN15 to 50 DN65 to 100
640cm² 1190-8789 1190-8790
320cm² 1190-8788 1190-8789
160,80,40cm² 1190-8788
Note
7.8 Preparation for return
shipment
Defective devices can be returned to
SAMSON for repair. Proceed as follows to
return devices to SAMSON:
1. Put the regulator out of operation (see
section9.1).
2. Decontaminate the regulator. Remove
any residual process medium.
3. Fill in the Declaration on Contamination.
The declaration form can be downloaded
from our website at uwww.samson.de>
SERVICE&SUPPORT>After-sales
Service.
4. Sendthedevicetogetherwiththelled-in
form to your nearest SAMSON
subsidiary. SAMSON subsidiaries are
listed on our website at
uwww.samson.de>Contact.