73
www.seuservice.com
Item Interval Reference
CABINET
Check Adjusters' contact with surface.
Daily 3
HANDLE MECHA Check lamps. Monthly 9
Check VOLUME VALUE. Monthly 9, 10-2
Check ADJUST GEAR engagement. Trimonthly 10-2
Greasing of GEAR. Trimonthly 10-3
ACCEL. & BRAKE Check VOLUME value. Monthly 9,11-1
Check ADJUST GEAR engagement. Trimonthly 11-1
Gear and Spring portion greasing. Trimonthly 11-2
PADDLE SHIFT Check switches. Monthly 9,12
COIN CHUTE TOWER Check COIN SW. Monthly 9
Coin insertion test. Monthly 13
Cleaning of COIN SELECTOR. Trimonthly 13
MONITOR Check adjustments.
Monthly or when moving.
6,9,14
Cleaning of CRT surfaces. Weekly 14-2
SEAT Applying grease to Seat Rail Trimonthly
Next page (FIG.16)
GAME BD MEMORY TEST. Monthly 9
Check settings. Monthly 9
Cabinet surfaces Cleaning As necessary. Next page
INTERIOR Cleaning Annually See above.
POWER SUPPLY PLUG Inspection and cleaning
16. PERIODIC INSPECTION TABLE
The items listed below require periodic check and maintenance to retain the performance of this
machine and to ensure safe business operation.
TABLE 16
Be sure to check once a year to see if Power Cords are damaged, the plug is
securely inserted, dust is accumulated between the Socket Outlet and the
Power Plug, etc. Using the product with dust as is accumulated can cause fire
and electric shock hazards.
Periodically once a year, request the place of contact herein stated or the
Distributor, etc. where the product was purchased from, as regards the internal
cleaning. Using the product with dust as is accumulated in the interior
without cleaning can cause a fire or accident. Note that cleaning the interior
parts can be performed on a pay-basis.