Detailed descriptions
16.1 Motherboard
SIMATIC HMI IPC677C
Operating Instructions, 04/2013, A5E02722710-04
199
16.1.4 External ports
; ; ; ; ; ;; ;
Figure 16-2 Connector pin assignment on the port
* Optional product variant
Table 16- 1
Interface Position Connector Description
USB 2.0 external X60
Lower USB channel 0, upper USB channel 1
Lower USB channel 2, upper USB channel 3
PROFIBUS/MPI external X4 9-pin, standard socket, electrically isolated interface
PROFINET external X3 Three RJ45 ports
Ethernet external X1
X2
First RJ45 port
Second RJ45 port
DVI-I external X70 26-pin socket
Compact Flash external X50 50-pin CF socket, types I / II
COM1 external X30 Serial port
USB ports, X60
The Universal Serial Bus interfaces have the following pinout:
USB interface
Pin no. Short description Meaning Input / Output
1 VCC + 5 V (fused) Output
2 – Data Data channel Input / Output
3 + Data Data channel Input / Output
4 GND Ground
The connectors are of type A.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI IPC677C and is the answer not in the manual?

Siemens SIMATIC HMI IPC677C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI IPC677C
CategoryIndustrial PC
LanguageEnglish

Related product manuals