Configuring the operating system
6.1 Configuring the operating system for the OP 73micro
OP 73micro, TP 177micro (WinCC flexible)
76 Operating Instructions, 09/2007, 6AV6691-1DF01-0AB0
Procedure
Proceed as follows:
1. Close the project.
2. Open the "Logon/Settings" menu.
3. Edit the settings.
4. Close the "Logon/Settings" menu.
6.1.3.2 Setting the delay
Requirements
"Info/Settings ▶ Logon/Settings ▶ Startup Delay" was selected from the Loader menu.
Principle
Startup Delay
Value: Sec.3
Figure 6-8 "Startup Delay" dialog
The delay defines the period which the HMI device automatically delays the startup of a
stored project.
When the value "0" is set, the project starts immediately. It is then no longer possible to call
the Loader after switching on the HMI device. To handle this situation, you must have
configured an operator control object you can use to close the project.
Valid range of values: 0 s to 60 s.
6.1.3.3 Setting the screen saver
Requirement
"Info/Settings ▶ Logon/Settings ▶ Screen saver" was selected from the Loader menu.
Principle
Screensaver
Value: Min.
0
Figure 6-9 "Screen saver" dialog
Use this dialog to set the activation delay for the screen saver.
Valid range of values: 5 min to 360 min. The screen saver is disabled when you set 0.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI TP 177micro and is the answer not in the manual?

Siemens SIMATIC HMI TP 177micro Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI TP 177micro
CategoryControl Panel
LanguageEnglish

Related product manuals