09.02 Start-Up
Siemens AG 6SE7087-6AK85-1AA0
4-25
Rectifier/Regenerating Unit Operating Instructions
4.3.1.2.3 Selecting the destinations for the status word (bits 0 - 31)
For the selection parameters P600 to P631, in which the destination of the appropriate bit can be specified,
then the indices are uniformly assigned as follows:
Index i001 Selecting a terminal on the CUR board (basic converter)
i002 Selecting a terminal on the SCI 1/2 board (option
)
Index i001 Selecting a terminal on the CUR board (basic converter)
Value Destination
0000 No destination
Factory setting, except P603
1001 CUR, BA1, -X104:17/18,
1002 CUR, BA2, -X104:19/20,
Factory setting, for P603
Index i002 Selecting a terminal on the SCI 1/2 board (option)
Value Destination
0000 No destination
Factory setting
4101 SCI 1 and 2,Slave 1, BA1
4102 BA2
4103 BA3
4104 BA4
4105 BA5
4106 BA6
4107 BA7
4108 BA8
4109 only SCI 2,Slave 1, BA9
4110 BA10
4111 BA11
4112 BA12
4201 SCI 1 and 2,Slave 2, BA1
4202 BA2
4203 BA3
4204 BA4
4205 BA5
4206 BA6
4207 BA7
4208 BA8
4209 only SCI 2,Slave 2, BA9
4210 BA10
4211 BA11
4212 BA12
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simovert 6SE70 Series and is the answer not in the manual?

Siemens Simovert 6SE70 Series Specifications

General IconGeneral
BrandSiemens
ModelSimovert 6SE70 Series
CategoryDC Drives
LanguageEnglish

Related product manuals