Connection 09.02
3-56 Siemens AG 6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit Operating instructions
3.8.4 Control/status word for 12-pulse mode (r599) and control word 2, bit 23
The following table shows how the bits of the control/status word for 12-pulse mode (r599) are formed from the
bits of control words 1 and 2 (r550, r551), the bits of status word 1 (r552), the bits of the first SST2 receive
data (r599 sent from the Peer-to-Peer partner) and the internal unit status with Boolean arithmetic or how these
bits are connected together (negation is represented with a slash) :
Control/status word for 12-pulse mode (r599)
Bit Logical linking (or meaning in the high state):
r599.0
r550.0 (ON or not OFF1) AND /r552.3 (no fault) AND r551.23 (12-pulse mode is selected)
r599.1
r550.1 (run condition or not OFF2) AND /r552.3 (no fault) AND r551.23 (12-pulse mode is selected)
r599.2
r550.2
r599.3
r552.2 (Message for RUN state)
r599.4
(for internal diagnostic purposes: 1, as long as trigger delay is running, as of Software Version 4.3)
r599.5
Message: Unit is a Rectifier/Regenarating Unit (high state: Unit is a comon rectifier)
(P070 100) (P070 101)
r599.6
Message: DC link forming or current identification is being carried out
r599.7
r550.7 (fault reset)
r599.8
r550.8 (typing 1 ON) AND /r552.3 (no fault) AND r551.23 (12-pulse mode is selected)
r599.9
r550.9 (typing 2 ON) AND /r552.3 (no fault) AND r551.23 (12-pulse mode is selected)
r599.10
r550.10 (PLC control)
r599.11
r550.11 (Ud-reduction requested)
r599.12
r552.10 (Message: "Regenerating ready") or
High when with 12-pulse mode selected (r551.23= 1), the unit is held in state r000 = "--" (because
"circuit identification" or "forming" is taking place on the partner unit, or because the unit is waiting
for the "run" state of the 12-pulse slave unit (while the slave unit is carrying out the earth short-
circuit test and the maximum waiting time of 5 s in state r000 = "--" has not yet elapsed))
r599.13
r552.3 (Message: NO fault)
r599.14
r552.14 (Message: "Motoring" (Rectifier bridge is carrying current or is ready to carry current or
neither rectifier nor regenerating bridge are carrying current))
r599.15
r550.15 (No external fault 1)
Table 13 Control/status word for 12-pulse mode (r599)
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simovert 6SE70 Series and is the answer not in the manual?

Siemens Simovert 6SE70 Series Specifications

General IconGeneral
BrandSiemens
ModelSimovert 6SE70 Series
CategoryDC Drives
LanguageEnglish

Related product manuals