09.02 Start-Up
Siemens AG 6SE7087-6AK85-1AA0
4-75
Rectifier/Regenerating Unit Operating Instructions
Error code Meaning
105 Indexed parameter
106 Request not implemented in drive
107 Text cannot be modified
108 Incorrect number of parameter values Applies to "Change all indices" request
The
index IND contains a "0" for non-indexed parameters; a 8-bit long index value is entered (in the low-order
byte) for indexed parameters.
Exception: In the case of cyclical PROFIBUS services, the L and H byte sequence is reversed (see "Start-up of
PROFIBUS boards").
Header
Trailer
Index
IND
Bit
15
Parameter value
PWE
Parameter identifier
PKE
Index, L byteIndex, H byte
An index value of 255 means that the request applies to all indices of the relevant parameter. In the case of a
modification request, the parameter values for all indices of the parameter must be transferred. Conversely, the
drive supplies all index values in its response to a read request.
The
parameter value PWE is treated like a double word (PWE1 and PWE2). The high word is set to 0 when a
single word is transferred.
Header
Trailer
Index
IND
PWE2PWE1
Parameter value
PWE
Parameter identifier
PKE