Parameter List 09.02
5-30 Siemens AG 6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit Operating Instructions
PNU
*
: Conf.
Par.
OP1S parameter name
Description
Value range
[phys. unit]
Selection text
Display
Indices
Factory-
setting
See
Modify
(access /
status)
P684
*
SCom/SCB Baud
Serial interfaces baud rate
1 300 Baud
2 600 Baud
3 1200 Baud
4 2400 Baud
5 4800 Baud
6 9600 Baud
7 19200 Baud
8 38400 Baud
9 57650 Baud
10 76800 Baud
11 93750 Baud
12 115200 Baud
13 187500 Baud
i001 = SST1: serial comm. interface 1 (CUR)
i002 = SCB: SCB, if P682=1, 2, 3
i003 = SST2: serial comm. interface 2 (CUR with PTP1 option)
PNU=2ACHex; Type=O2; Scaling: 1Hex
=
1
1 to 813
300 Bd
600 Bd
1200 Bd
2400 Bd
4800 Bd
9600 Bd
19200 Bd
38400 Bd
57650 Bd
76800 Bd
93750 Bd
115200 Bd
187500 Bd
2
i001=6
i002=6
i003=13
3/ BR
3/ B
P685
*
SCom/SCB #PKWDat
Number of words (16 bit) of the parameter data part in the net data block of
the telegram.
0: No parameter data part in the telegram
3, 4 Parameter data part is 3 (parameter identifier, Ind, parameter
value), 4 words long
127 Variable parameter data length for the transfer of parameter
description and texts
i001 = SST1: serial comm. interface 1 (CUR)
i002 = SCB: SCB, if P682=1, 2
PNU=2ADHex; Type=O2; Scaling: 1Hex
=
1
0 to 127 2
i001=127
i002=127
3/ BR
3/ B
P686
*
SCom/SCB # PrDat
Number of words (16 bits) of the process data part in the net data block of
the telegram.
i001 = SST1: serial comm. interface 1 (CUR)
i002 = SCB: SCB, if P682=1, 2, 3
PWE=0 means that no process data are expected in the USS protocol and
that none are sent.
i003 = SST2: serial comm. interface 2 (CUR with PTP1 option), if
Peer-to-Peer protocol is selected (P688=1), from 1 to 5 net
data words can be sent.
PNU=2AEHex; Type=O2; Scaling: 1Hex
=
1
0 to 16 3
2
3/ BR
3/ B
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents