WARNING
Exceeded maximum permissible operating pressure
Risk of injury or poisoning.
The maximum permissible operating pressure depends on the device version, pressure limit
and temperature rating. The device can be damaged if the operating pressure is exceeded.
Hot, toxic and corrosive process media could be released.
Ensure that maximum permissible operating pressure of the device is not exceeded. Refer
to the information on the nameplate and/or in Technical data (Page 49).
CAUTION
External stresses and loads
Damage to device by severe external stresses and loads (e.g. thermal expansion or pipe
tension). Process media can be released.
Prevent severe external stresses and loads from acting on the device.
5.1.1 Installation location requirements
NOTICE
Strong vibrations
Damage to device.
In installations with strong vibrations, mount the transmitter in a low vibration environment.
CAUTION
Aggressive atmospheres
Damage to device through penetration of aggressive vapors.
Ensure that the device is suitable for the application.
Installing/mounting
5.1 Basic safety notes
SITRANS Probe LU240 with mA/HART
18 Compact Operating Instructions, 10/2018, A5E42673704-AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS L LU240 and is the answer not in the manual?

Siemens SITRANS L LU240 Specifications

General IconGeneral
BrandSiemens
ModelSITRANS L LU240
CategoryTransmitter
LanguageEnglish

Related product manuals