TC35i: Migration from TC35 to TC35i
PRELIMINARY
TC35_TC35i_MIG_01_V01.01 29.1.2003 Page 24 of 34
# AT Command
32 ATV Set result code format mode
33 ATX Set CONNECT result code format and call monitoring
34 ATZ Set all current parameters to user defined profile
35 AT&C Set circuit Data Carrier Detect (DCD) function mode
36 AT&D Set circuit Data Terminal Ready (DTR) function mode
37 AT&F Set all current parameters to manufacturer defaults
38 AT&S Set circuit Data Set Ready (DSR) function mode
39 AT&V Display current configuration
40 AT&W Store current configuration to user defined profile
Differing parameters
TC35i
User profile extended to include the following
commands:
AT\V, AT+ICF, AT+IFC, AT\Q, AT%D, AT^STPB.
TC35
Commands: AT\V, AT+ICF, AT+IFC, AT\Q, AT%D
are either not available or not included within user
profile.
41 AT+GCAP Request complete TA capabilities list
42 AT+GMI Request manufacturer identification
43 AT+GMM Request TA model identification
44 AT+GMR Request TA revision identification of software status
45 AT+GSN Request TA serial number identification (IMEI)
46 AT+ILRR Set TE-TA local rate reporting
47 AT+IPR Set fixed local rate
Differing parameters (factory defaults); minor wording differences
TC35i
<rate>
Factory settings, fixed: AT+IPR=57600
(230,4kbps possible in case of available memory)
TC35
<rate>
Factory settings, autobauding: AT+IPR=0
5.2.2 AT Commands for FAX
Table 5-2: AT commands for FAX
# AT Command
48 AT+FBADLIN Bad Line Threshold
49 AT+FBADMUL Error Threshold Multiplier
50 AT+FBOR Query data bit order
51 AT+FCIG Query or set the Local polling id
52 AT+FCLASS Fax: Select, read or test service class
53 AT+FCQ Copy Quality Checking
54 AT+FCR Capability to receive
55 AT+FDCC Query or set capabilities