5.2.5 Siemens defined AT commands for enhanced functions
Table 5-5: Siemens defined AT commands
# AT Command
138 AT+CXXCID Display card ID (identical to AT^SCID)
Differing implementation
TC35i
Available without entering the PIN.
TC35
PIN required.
139 AT^MONI Monitor idle mode and dedicated mode
Differing parameters; minor differences in wording of command syntax description; differing
notes
140 AT^MONP Monitor neighbour cell
141 AT^SACM Advice of charge and query of ACM and ACMmax
142 AT^SBC Battery charging / discharging and charge control
143 AT^SCID Display SIM card identification number
Differing implementation
TC35i
Available without entering the PIN.
TC35
PIN required.
144 AT^SCKS Set SIM connection presentation mode and query SIM connection status
145 AT^SCNI List Call Number Information
146 AT^SCTM Set critical operating temperature presentation mode or query temperature
Differing parameters, notes and examples
TC35i
TC35i has two additional parameters:
<p> output/suppress <temp> in read syntax
<temp> board temperature, Celsius
<p> 0 Suppress output of <temp> in test and read command.
1 Output <temp> in test and read command.
<temp> Board temperature in Celsius. Is comprised between the lowest
temperature limit and the uppermost temperature limit.
Syntax:
AT^SCTM=<n>[,<p>]
TC35
N/A
147 AT^SDLD Delete the .last number redial. memory
148 AT^SHOM Display Homezone
149 AT^SLCD Display Last Call Duration
150 AT^SLCK Facility lock
151 AT^SMGL List SMS messages from preferred storage
152 AT^SMGO Set or query SMS overflow presentation mode or query SMS overflow
153 AT^SMGR Read SMS message without set to REC READ
154 AT^SMONC Cell Monitoring
155 AT^SMSO Switch off mobile station
156 AT^SM20 Set M20 Compatibility
Differing parameters
TC35i
Additional parameter:
<n> Call compatibility parameter
0
Compatible to x35 Mobile
Phones
1 Compatible to M20
<m> Short message write compatibility
parameter.
0
Compatible to x35 Mobile
Phones
1 Compatible to M20
TC35
<n>
0 Compatible to x35/37mobiles.
If this mode is active, TA returns OK right after
attempting a call.
1 Compatible to M20.
If the M20 mode is active, TA returns OK once the
call is successfully set up. Issuing any command
before TA returns OK will cancel the call setup.
157 AT^SNFD Set audio parameters to manufacturer default value
158 AT^SNFI Set microphone path parameters
159 AT^SNFM Mute microphone
160 AT^SNFO Set audio output (= loudspeaker path) parameter
161 AT^SNFPT Call progress tones
162 AT^SNFS Select audio hardware set
Differences in command syntax description; differing notes

Table of Contents

Other manuals for Siemens TC35i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens TC35i and is the answer not in the manual?

Siemens TC35i Specifications

General IconGeneral
BrandSiemens
ModelTC35i
CategoryModem
LanguageEnglish

Related product manuals