- 24 -
No.JXC※-OMX0011-A
5. PWR: Power supply plug
5.1 Power supply plug specifications
The specifications of the power plug supplied with the controller are shown below.
The positive control power.
The positive power for the electric
actuator motor to be supplied via
the controller.
The positive power for Stop signal.
The negative common power for
M24V, C24V, EMG and LK RLS.
The positive power for lock release.
Equivalent to Phoenix Contact: FMC1,5/3-ST-LR
5.2 Electric wire specifications
Prepare the wiring according to the following specifications (to be prepared by the user).
Single, stranded wire ⇒ AWG20 (0.5mm
2
)
The rated temperature for the insulation coating: 60
o
C or more,
Cable sheath O.D. ø2.5mm or less
Multiple electric wires should not be connected to one terminal.
Arrange wiring so that conductors of each terminal do not contact other lines.
After wiring the power supply plug, connect it to PWR power connector of the controller.
Refer to 5.3. Power supply plug for wiring.