12.2 Alarm details
Controller
Setting Software
(code)
Teaching
box
Group
How to
deactivate
Alarm contents/ Countermeasure
Drive data value
is wrong
(01-048)
Operation
data error
B
RESET
input
<Contents>
The step data is in-correct for the following conditions
(Assignable value range)
(1) "Area1" < "Area2"
(If both "Area1 and Area2" is 0, the alarm will not be
activated.)
(2) "Trigger LV" ≤ "Pushing force"
(If Pushing force< "Trigger LV" at the time of "Pushing
force" = 0, the alarm will not be activated.)
(3) Minimum speed of the electric actuator ≤ "Pushing
speed" ≤ "Speed"
(4) "Pushing speed" ≤ Maximum pushing speed of the
electric actuator
(5) Pushing force Minimum pushing force of the electric
actuator
(6) Basic parameters "Max force" Minimum pushing force
of the electric actuator
(7) Basic parameters "Max force" "Trigger LV"
<Countermeasure>
Modify the step data and basic parameters setting.
Caution
Please confirm this pushing force and minimum speeds
of Data maximum speed and 0 or more of the electric
actuator with the electric actuator manual or the
catalog.
The Parameter
value is incorrect
(01-049)
System
parameter
error
B
RESET
input
<Contents>
The basic parameter is not correct for the following
condition: (Assignable value range)
(1) Stroke (-) < Stroke (+)
(2) W-Area 1 < W-Area2
(If both W-Area1 and W-Area2 is 0, the alarm will not
be activated.)
(3) Maximum pushing force < Maximum pushing force of
the electric actuator
<Countermeasure>
Modify the basic parameter setting.
Caution
Please refer to the manual or the catalogue of the
electric actuator for the max/ min pushing force / speed
for the electric actuator.
The deceleration
value is too
small.
(01-050)
Small
Dec
B
RESET
input
<Contents>
Step data in which a deceleration speed exceeding the
stroke limit is specified.
<Countermeasure>
Modify the Deceleration value to a value with a sufficient
margin so that the electric actuator can stop within the
stroke limit.