- 27 -
No.JXC-OMX0011-A
(2) Example circuit 2 - multiple controllers (Relay contact (1))
If the system where this controller is installed has a stop circuit for whole system, or if the system has
multiple controllers with individual power supply, relay contacts should be made between the 24 VDC
controller power supply and the EMG terminal of the power supply plug.
Caution
When shutdown is input, the controller stops with maximum deceleration, then the motor is turned off.
LK RLS (6)
Ry
Power supply plug
(the 3
rd
controller)
(1) C 24V
(2) M 24V
0V (4)
(3) EMG
LK RLS (6)
Ry
Power supply plug
(the 2
nd
controller)
(1) C 24V
(2) M 24V
0V (4)
(3) EMG
LK RLS (6)
Ry
Power supply plug
(the 1
st
controller)
(1) C 24V
(2) M 24V
0V (4)
(3) EMG
(Circuit example: The figure below shows the stopped state.)
24 VDC
Ry
0V
stop
switch
Surge suppressor
Reset switch
for stop
Ry U
24VDC
0V
Controller
power supply
24VDC
0V
Controller
power supply
24VDC
0V
Controller
power supply