EasyManuals Logo
Home>Sony>Switch>XKS-8440

Sony XKS-8440 User Manual

Sony XKS-8440
569 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #167 background imageLoading...
Page #167 background image
167
DME Wipe Snapshots
You can save a snapshot of a DME wipe pattern together
with all modifier and pattern limit settings in a dedicated
register for recall when required.
There are ten DME wipe snapshot registers on each
switcher bank.
Use the Flexi Pad control block in each switcher bank or
the menu to save and recall DME wipe snapshots.
DME Wipe Snapshot Operations
(Flexi Pad Control Block)
Pressing the [DME WIPE] button in the Flexi Pad control
block switches the memory recall section to DME wipe
snapshot operation mode for saving, recalling, and
deleting DME wipe snapshots.
DME wipe snapshot operations are the same as wipe
snapshot operations. However, a 4-digit pattern number is
entered to select DME wipe patterns.
For details about the method of operation, see “Wipe
Snapshot Operations (Flexi Pad Control Block)”
(page 152).
DME Wipe Snapshot Operations
(Menu)
You can save, recall, and delete DME wipe snapshots in
the DME Wipe >DME Wipe Snapshot menu on each
switcher bank.
DME wipe snapshot operations are the same as wipe
snapshot operations. However, a 4-digit pattern number is
entered to select DME wipe patterns.
For details about the method of operation, see “Wipe
Snapshot Operations (Menu)” (page 153).
Creating User
Programmable DME
Patterns
With a user programmable DME, you can use DME effects
created through the use of keyframes for a transition on the
switcher.
Note the following points when creating a keyframe effect
for use as a user programmable DME pattern.
Register numbers and pattern numbers
When saving a keyframe effect as a user programmable
DME, specify the register number corresponding to the
pattern number.
For details about registers, see “Registers” (page 297).
Global channel keyframe effects
If an effect with the same number as the reference channel
is present on the DME global channel, executing the user
programmable DME will also execute the effect on the
global channel simultaneously.
When executing a user programmable DME, take note of
whether the effect is present on the global channel.
User Programmable DME Transition
Mode
To create a user programmable DME, it is necessary to set
the transition mode (the way in which the effect moves).
To set the transition mode, use the Key Frame >DME User
PGM menu (6114).
For details about the method of operation, see “Transition
Mode Settings for User Programmable DME” (page 314).
The following transition modes are available.
Execution mode Register number Pattern number
1-channel mode 101 to 199 1901 to 1999
2-channel mode 201 to 299 2901 to 2999
3-channel mode 301 to 399 3901 to 3999

Table of Contents

Other manuals for Sony XKS-8440

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony XKS-8440 and is the answer not in the manual?

Sony XKS-8440 Specifications

General IconGeneral
BrandSony
ModelXKS-8440
CategorySwitch
LanguageEnglish

Related product manuals