www.stiebel-eltron.com DCE 11/13| DCE 11/13 RC| DCE 11/13 H | 27
INSTALLATION
Commissioning
11. Commissioning
11.1 Initial start-up
1.
2.
4.
3.
5.
6.
≥ 60 s
°C
40
50
60
30
20
°C
40
50
60
30
20
DCE 11/13
DCE 11/13 H
DCE 11/13
DCE 11/13 H
D0000039994
Fill the appliance by running the tap until the pipework and
appliance are free of air. Open the draw-off valve several
times.
Activate the electronic safety switch (AE3). On delivery, the
electronic safety switch is in the tripped position.
Only for the DCE11/13 | DCE11/13H: Insert the temperature
selector plug into the "set temperature" PCB. Note the align-
ment of the wires.
Fit the appliance cover by positioning it and pressing against
it until the locking hooks at the top and bottom click into
place. Check that the locking hooks have clicked into place.
Switch the mains electrical power ON.
Only for the DCE11/13 | DCE11/13H: Turn the temperature
selector to its left-hand and right-hand end-stop.
Carry out a tightness check.
Tick the selected connected load and rated voltage on the
type plate. Use a ballpoint pen to do this.
Check the function of the appliance.
11.2 Appliance handover
Explain the functions of the appliance to the user. Show the
user how to operate the appliance.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over these instructions.
11.3 Recommissioning
!
Material losses
Following an interruption to the water supply, recommis-
sion the appliance by carrying out the following steps.
This will prevent destruction of the bare wire heating
system.
Disconnect the appliance from the power supply by removing
the fuses/tripping the MCBs.
Open the tap for one minute until the appliance and its up-
stream cold water inlet line are free of air.
Switch the mains electrical power back ON again.
See chapter "Installation/ Commissioning".
12. Shutdown
Disconnect the appliance from the mains at the MCB/fuse in
the fuse box.
Drain the appliance (see chapter "Installation/
Maintenance").
13. Installation options
13.1 Adjustable connected load
13kW
11kW
D0000039993
Plug in the coding card in accordance with the selected con-
nected load.

Table of Contents

Other manuals for STIEBEL ELTRON DCE 11/13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON DCE 11/13 and is the answer not in the manual?

STIEBEL ELTRON DCE 11/13 Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelDCE 11/13
CategoryWater Heater
LanguageEnglish

Related product manuals