30 AN650A/K7 (’07-MODEL)
ISC VALVE PRE-SET
When removing or replacing the ISC valve, set the ISC valve in
the following procedures:
1) Turn the ignition switch ON.
2) Set up the SDS tool. (Refer to the SDS operation manual for
further details.)
3) Click “Active control”.
4) Click “ISC learned value reset”
1.
5) Click “Reset” button
2 to clear the ISC learned value.
NOTE:
The learned value of the ISC valve is set at PRE-SET position.
6) Close the SDS tool.
7) Turn the ignition switch OFF.
NOTE:
The ISC valve opening initialization is automatically started after
the ignition switch is turned OFF.