55--6666
③ Start or End B / T Length
This function is to set the length of a stitch while bartack is performed. .
For thin or wool fabric, set the value at 0.8[mm], and the first stitch plaiting and trimming can be effectively
performed.
– The default is 0.8[mm], and the value can be adjusted from 0.6 to 0.8[mm] by the unit of 0.1[mm].
(4) Sound volume
The function is to set the volume of the sound issued when the power is turned on/off or when a menu is
selected.
– The default is OFF (0), and the value can be set at the range of 1 to 10.
(5) Head select
This function is to select the heads you desire to use.
It is not available in this type of machine.
(6) Thread Select
This function is to select appropriate threads by conditions.
– The default is Normal(0). For wool, select Wool(1).
(7) Time Setting
This function is to change the date and time displayed on the upper right side of the screen.
On the Other Settings menu, select No. 7, and the screen where date and time can be set appears as in <Fig.
5.4.7-4>.
Use the menu move buttons , , and , for setting.
For date and time setting, see “4.4.2 Date/Time Change”.