6 – Modules
0 +48V button
o This shows the +48V button when the input source of the
selected module is “ANALOG” or “SB-16D connected by
built-in Dante”.
If the input sources of the selected module for both
the left and right channels are “ANALOG” or “SB-16D
connected by built-in Dante”, this shows the left channel
setting.
o Touch and hold the +48V button to turn phantom power
(+48V) on/off. (Default: off)
If the input sources of the selected module for both
the left and right channels are “ANALOG” or “SB-16D
connected by built-in Dante”, this switches phantom
power on/off for both channels.
When phantom power is on, the button will be
highlighted.
o A black button that cannot be operated will be shown if
the input source is an SB-16D for which control privileges
are not held.
q PAD button
o This shows the PAD button when the input source of the
selected module is “ANALOG” or “SB-16D connected by
built-in Dante”.
If the input sources of the selected module for both
the left and right channels are “ANALOG” or “SB-16D
connected by built-in Dante”, this shows the left channel
setting.
o Tap this button to turn the -20dB pad on/off. (Default: off)
If the input sources of the selected module for both
the left and right channels are “ANALOG” or “SB-16D
connected by built-in Dante”, this switches the -20dB pad
on/off for both channels.
When this button is on, it will appear highlighted.
o A black button that cannot be operated will be shown if
the input source is an SB-16D for which control privileges
are not held.
NOTE
When the pad is switched on/off, the Analog GAIN value will
be controlled as shown below so that it changes as little as
possible.
When Analog Reference Level is +6 dBu and Digital
Reference Level is -9 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +3 – +37 Same value
PAD ON/Analog GAIN: -17 – +2 +3
PAD OFF/Analog GAIN: +38 – +57 +37
When Analog Reference Level is +4 dBu and Digital
Reference Level is -20 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +12 – +46 Same value
PAD ON/Analog GAIN: -8 – +11 +12
PAD OFF/Analog GAIN: +47 – +66 +46
When Analog Reference Level is +4 dBu and Digital
Reference Level is -18 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +10 – +44 Same value
PAD ON/Analog GAIN: -10 – +9 +10
PAD OFF/Analog GAIN: +45 – +64 +44
When Analog Reference Level is +4 dBu and Digital
Reference Level is -16 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +8 – +42 Same value
PAD ON/Analog GAIN: -12 – +7 +8
PAD OFF/Analog GAIN: +43 – +62 +42
When Analog Reference Level is +4 dBu and Digital
Reference Level is -14 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +6 – +40 Same value
PAD ON/Analog GAIN: -14 – +5 +6
PAD OFF/Analog GAIN: +41 – +60 +40
When Analog Reference Level is 0 dBu and Digital
Reference Level is -20 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +8 – +42 Same value
PAD ON/Analog GAIN: -12 – +7 +8
PAD OFF/Analog GAIN: +43 – +62 +42
When Analog Reference Level is 0 dBu and Digital
Reference Level is -18 dBFS
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +6 – +40 Same value
PAD ON/Analog GAIN: -14 – +5 +6
PAD OFF/Analog GAIN: +41 – +60 +40
w Analog GAIN knobs
o When the input source of the selected module is
“ANALOG” or “SB-16D connected by built-in Dante”, this
will show analog gain knobs for each channel of this unit
or the SB-16D. These can be used to adjust input levels of
MIC/LINE input jacks.
Turn LCD knob 1 (lit red) to adjust it.
When Analog Reference Level is +6 dBu and Digital
Reference Level is -9 dBFS
PAD button setting Range
OFF +3 (default) – +57
ON -17 – +37
118 TASCAM Sonicview 16/Sonicview 24 V1.1.0