16 – Parameter tables
Function Parameter steps
Fine Step
(when LCD knob
turned without being
pressed)
Coarse Steps
(when LCD knob
turned while being
pressed)
FADER LEVEL -∞ dB, -120 dB – +10.0 dB 1024
1 point/click
(-10 dB - +10 dB: 0.05
dB/click)
40 point/click
(-10 dB - +10 dB: 2
dB/click)
MUTE OFF/ON
MAIN L/R Assign OFF/ON
PAN/BAL L100 – C – R100 201 1 point/click 10 point/click
IMAGE
STEREO 100% – MONO – REVERSE
100%
101 2%/click 10%/click
MODE STEREO/L-MONO/R-MONO 3
Send
Send Level -∞ dB, -120 dB – +10.0 dB 1024
1 point/click
(-10 dB - +10 dB: 0.05
dB/click)
40 point/click
(-10 dB - +10 dB: 2
dB/click)
Send Pan L100 – C – R100 201 1 point/click 10 point/click
Send Switch OFF/ON
Send Point PRE/POST
DCA 8 DCAs
Mute Group 8 Groups
Stereo Link OFF/ON
o Preamp analog gain for every reference level
When Analog Reference Level is +6 dBu and Digital Reference Level is -9 dBFS
When PAD OFF +3 dB – +57 dB
When PAD ON -17 dB – +37 dB
When Analog Reference Level is +4 dBu and Digital Reference Level is -20 dBFS
When PAD OFF +12 dB – +66 dB
When PAD ON -8 dB – +46 dB
When Analog Reference Level is +4 dBu and Digital Reference Level is -18 dBFS
When PAD OFF +10 dB – +64 dB
When PAD ON -10 dB – +44 dB
When Analog Reference Level is +4 dBu and Digital Reference Level is -16 dBFS
When PAD OFF +8 dB – +62 dB
When PAD ON -12 dB – +42 dB
When Analog Reference Level is +4 dBu and Digital Reference Level is -14 dBFS
When PAD OFF +6 dB – +60 dB
When PAD ON -14 dB – +40 dB
When Analog Reference Level is 0 dBu and Digital Reference Level is -20 dBFS
When PAD OFF +8 dB – +62 dB
When PAD ON -12 dB – +42 dB
When Analog Reference Level is 0 dBu and Digital Reference Level is -18 dBFS
When PAD OFF +6 dB – +60 dB
When PAD ON -14 dB – +40 dB