Creating a mean (average) AV
Set the number of seconds during which an average should be calculated. (ex works = 1.0s)
AV1 1.0 Create an average of sensor S1 for 1.0 seconds
For simple measurements, 1.0-2.0 should be selected.
A large average slows everything down and is only recommended for
the sensors for the heat counter.
The measurement of the ultra fast sensor for the preparation of hot
water also requires a fast evaluation of the signal. Hence, the determination of average of the
sensor is reduced by the programs 16 and 17 to 0.4, although fluctuations will then occur in
the display. No averaging is possible for the volume flow encoder, VSG.
Setting range: 0.0 to 6.0 seconds in increments of 0.1 seconds
0.0 = no average
System protection functions SYS PF
Collector excess
temperature limiter
Frost protection
ON/OFF
Shut-down thresh-
old
Switch-on thresh-
old
ON/OFF
Switch-on thresh-
old
Shut-down thresh-
old

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technische Alternative ESR 31 Series and is the answer not in the manual?

Technische Alternative ESR 31 Series Specifications

General IconGeneral
BrandTechnische Alternative
ModelESR 31 Series
CategoryControl Unit
LanguageEnglish

Related product manuals