27
RTH Radiation value (radiation threshold) in W/m
2
above which rinsing is allowed.
Without a radiation sensor, the computer calculates the necessary temperature
increase for the long-term mean that launches rinsing from this value.
(ex works = 150W/m
2
)
Adjustment range 0 to 990 W/m² in 10 W/m² steps
PRT Pump run-time (rinsing time) in seconds. During this time, the pump should
have pumped roughly half of the content of the collector’s heat transfer medium
past the collector sensor. (ex works = 15s)
Adjustment range 0 to 99 seconds
INT(max) Maximum allowable interval between two rinses. This time is automatically
reduced according to the temperature increase after rinsing. (ex works = 20min)
Adjustment range 0 to 99 minutes
NSA Number of start attempts (= counter). The system is automatically reset for a
start attempt if the last start attempt was more than four hours ago.
After-running time ART
During the start phase, the pumps may repeatedly switch on and off for a long time, espe-
cially with solar and heating systems with long hydraulic system lines. This response can be
reduced by using a speed control or increasing the pump after-run time.
After-running time
output
AT After-running time output (ex works = 0)
Setting range: 0 (no after-running time) to 9 minutes in increments of 10 seconds

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technische Alternative ESR 31 Series and is the answer not in the manual?

Technische Alternative ESR 31 Series Specifications

General IconGeneral
BrandTechnische Alternative
ModelESR 31 Series
CategoryControl Unit
LanguageEnglish

Related product manuals