Page #69 background imageLoading...
Page #69 background image
Ad
j
ustme
n
t
Procedur
e-2235
Service
Horizontal
Α
T
R
IGG
ER
VA
R
H
O
L
DO
FF
N
O
RM
M
ode
Ρ
-
ΡAU
TO
S
L
O
PE
O
U
T
LEVEL
M
idrange
Α
&
Β
ΙΝΤ
VER
T
M
OD
E
Α
SO
UR
CE
ΙΝΤ
P
O
WER
S
UPPL
Y
A
N
D
C
R
T
DIS
PL
AY
E
qui
p
ment
R
eq
u
i
r
e
d
(See
Ta
b
le
4-1)
:
L
eveled
Sine-
W
ave Generator
(Item
2)
Digital
V
oltmeter
(Item
10)
Time-
M
ar
k
Generator
(Item
3)
DC
V
oltmeter
(item
12)
50-
Ω
BN
C
Cable
(Item
4)
Screw
d
river
(Item
13)
50-
Ω
BN
C
Termination
(Item
5)
at
the
back
of
this
manual
for
location
of
test
p
oints
and
a
djustments
.
I
N
ITIA
L
CO
NTR
O
L
S
E
TTI
N
GS
α
.
Con
n
ect
t h
e
digital
voltmeter
low
lead to
ch
assis
ground
and
connect
t
he
volts
lead
to
t
he
-8
.6-V
s
upp
ly
V
ertical
(
ΤΡ
961)
.
P
OSITIO
N
(
b
ot
h
)
M
i
d
ra
nge
VER
TICA
L
M
OD
E
C
H
1
C
H
1
V
O
L
TS/DI
V
5
m
V
b
.
C
HE
CK
-
V
oltmeter
r
eading
is
-8
.56
to
-8
.64
V
.
If
C
H
1
V
O
L
TS/DI
V
V
a
r
iable
CA
L
dete
n
t
t
h
e
reading
is
wit
h
in
t
h
ese
limits,
sk
i
p
to
p
art
d
.
C
h
annel
1
AC-G
N
D-DC
G
ND
c
.
AD
JU
ST-T
he
-8
.6
V
A
dj
pote
n
tiometer
(
R
938)
fo
r
α
P
OSITIO
N
M
id
r
ange
voltmeter
reading
of
-8
.6
V
.
H
O
R
IZO
N
TA
L
M
OD
E
Α
Α
S
E
C/DI
V
Χ
-
Υ
S
E
C/DI
VV
aria
b
le
CA
L
detent
Χ
10
M
agnifier
Off
(
k
no
b
i
n)
d
.
C
HE
C
K
-
V
oltage
levels
of
t
he
remaining
p
ower
su
p
-
p
lies
liste
d
in
Tab
le
5-2 are
wit
h
in
t
he
specifie
d
limits
.
PR
OC
ED
URE
ST
EPS
1
.
C
h
ec
k
/A
d
ju
st P
owe
r
S
upp
ly
DC
L
evels
(
R
938)
ΝΟΤΕ
See
AD
JU
ST
MEN
T L
OCATIO
NS
1
P
owe
r
S
u
pply
-8
.6
V
+5
.2
V
+8
.6
V
+30
V
+100
V
Ta
b
le
5-2
P
ower
S
u
pp
ly
L
imits
Test
P
oi
n
t
ΤΡ
961
W968
W
960
W956
W
954
R
ea
d
i
ng
(
V
olts)
-8
.56
to
-8
.64
+5
.04
to
+5
.36
+8
.43
to
+8
.77
+29
.1
to
+30
.9
+97
.0
to
+103
.0
R
eview
the
information
at
the
beginning
of
the
Adjust-
ment
P
rocedure
b
efore
starting
this
step
.
e
.
Disconnect
t
he
test
equipment
from
t
h
e
i
nstrument
.

Table of Contents

Other manuals for Tektronix 2235

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2235 and is the answer not in the manual?

Tektronix 2235 Specifications

General IconGeneral
BrandTektronix
Model2235
CategoryTest Equipment
LanguageEnglish

Related product manuals