EasyManuals Logo
Home>Tektronix>Test Equipment>2235

Tektronix 2235 User Manual

Tektronix 2235
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
A
dju
stme
n
t
Pr
oced
ur
e-2235
Service
2
.
C
h
ec
k
H
ig
h
-
V
oltage
S
up
p
ly
c
.
Set
t
he
generator
to
p
ro
d
uce α 50-
kH
z,
4-division
display
.
W
A
RN
I
NG
Instrume
n
t
must
be
tur
n
ed
off
w
hen
removing
o
r
re-
placing
t
h
e
crt
cover
and
ca
p
.
b
.
C
HE
C
K
-
V
oltmeter
readi
n
g
is
b
etwee
n
-1900
V
and
-2100
V
.
3
.
Ad
j
ust
C
RT
Grid
Bias
(
R
851)
b
.
Ad
j
ust
t
h
e
front-panel
F
OC
US
control
to
p
roduce α
well-
d
efined
dot
.
c
.
R
otate
t
he
Α
I
NT
EN
SITY
con
trol
fully
counter
cloc
kwise
.
e
.
Disconnect
the
50-
Ω
termination
from
the
ΕΧΤ
Ζ
AXIS
INPUT
connector
.
4
.
Adjust
Astigmatism
(R874)
α
.
Set
:
Α
INTENSITY
V
isible
display
CH
1
V
OLTS/DIV
5
mV
C
hannel
1
AC-GND-DC
DC
Α
S
E
C/DI
V
5
μs
d
.
AD
JU
ST-Astig
(
R
874)
and
t
he
front-panel
F
OC
U
S
control
for
t
h
e
b
est
defi
ned
wavefo
r
m
.
e
.
Disconnect
t
he
test
equi
p
ment
from
t
h
e
instrume
n
t
.
α
.
R
emove
t
he
crt
cover and ca
p
and
co
nn
ect
α
do
volt-
5
.
Ad
j
ust
T
r
ace
Alig
n
ment
mete
r
cap
able
of
measuring
at
least
-2500
V
b
etween
pi
n
α
.
P
osition
t
h
e
trace
to
t
h
e ce
n
ter
h
orizo
n
tal
graticule
2
of
t
he
crt
sock
et
and ch
assis
ground
.
P
i
n 2
of
t
h
e
crt
is
line
.
negative
wit
h
res
p
ect
to
t
he ch
assis
.
b
.
AD
JU
ST-T
h
e
fro
n
t-
p
anel
TR
AC
E R
OTATIO
N
co
n
-
trol
for
o
p
timum
alignment
of
t
he
trace
wit
h
t
he cente
r
h
ori-
zon
tal
graticule
li
n
e
.
c
.
Disconnect
t
h
e
voltmeter
leads
a
nd
re
p
lace
t
h
e
crt
cap
6
.
Ad
ju st
Geometry
(
R
870)
and
cover
.
α
.
Set
:
C
H
1
V
O
L
TS/DI
V
50
m
V
ΑS
E
C/DI
V
0
.1
ms
α
.
Connect
α
50-
Ω
termination
to
t
h
e
ΕΧΤ
Ζ
AXIS
I
NPU
T
connector
locate
d on
t
he
rear
p
anel
.
b
.
Connect
50-
Ει
s
time
mar
k
ers
fr
om
t
he time-mark
gen-
erator
via
α
50-
Ω
cable
an
d
α 50-
Ω
terminatio
n
to
t
h
e
C
H
1
ORΧ
in
p
ut
connector
.
c
.
Ad
j
ust
t
he
C
h
annel
1
P
OSITIO
N
cont
r
ol
to
p
osition
t
he
b
aseline
p
art
of
t
he
display
below
t
h
e
bottom
h
o
r
izontal
graticule
line
.
d
.
Ad
j
ust
t
h
e
S
E
C/DI
V
V
aria
b
le
control
for
5
mar
k
e
r
s pe
r
d
i
visio
n
.
d
.
ADJUST-Grid
B
ias
(R851)
for
α
visible
dot
.
Then
b
ack
off
the
Gri
d
B
ias
p
otentiometer
until
the dot
just
disappears
.
e
.
ADJUST-Geom
(R870)
for
minimum
curvature
of
the
time
markers
at
the
left
and
right
edges
of
the
graticule
.
f
.
Set
the
Channel
1
AC-GND-DC
switch
to
GND
.
g
.
ADJUST-Geom
(R870)
for
minimum
curvature
of
the
b
aseline trace
when
positioned
at
the top
and
b
ottom
hori-
zontal
graticule
lines
using
the
Channel
1
P
OSITION
control
.
h
.
Set the
Channel
1
AC-GND-DC
switch
to
DC
.
i .
R
ep
eat
parts
e
t
h
roug
h h
fo
r
op
tim
u
m
comp
r
omise
be-
b
.
Co
n
nect
50-As
time
mar
k
ers
fr
om
t
he
time-mar
k gen-
tween
t
he
vertical
and
h
orizo
n
tal
displays
.
erator
via
α
50-
Ω
cable
an
d α
50-
Ω
termi
n
ation
to
t
he
C
H
1
O
R
Χ
i
np
ut
connector
.
j
.
Disconnect
t
h
e
test
eq
uipme
n
t f
r
om
t
he
instr
u
ment
.

Table of Contents

Other manuals for Tektronix 2235

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2235 and is the answer not in the manual?

Tektronix 2235 Specifications

General IconGeneral
BrandTektronix
Model2235
CategoryTest Equipment
LanguageEnglish

Related product manuals