AIR FORCE
T033A1-13-496-1
NAVELEX
0969-LP-170-0010
Preparation
For Use
and
Shipment
TOP OF
INSTRUMENT
NOTE: THE
FULL
LENGTH SLOT
REMOVAL INSTRUCTIONS
UNSCREW
FOUR CORNER THUMBSCREWS
(DO NOT UNSCREW COMPLETELY OUT
OF PLASTIC IMPLOSION
RETAINER).
PULL
IMPLOSION RETAINER WITH
FILTER FORWARD AWAY FROM CRT FACEPLATE.
REMOVE
FILTER BY LIFTING IT
OUT
OF THE IMPLOSION RETAINER.
INSTALLATION
INSTRUCTIONS
©
©
©
INSTALL
FILTER
IN
NOTCHES ON IMPLOSION
RETAINER WITH THE BLACK MASK TOWARD
THE CRT.
POSITION
IMPLOSION RETAINER ON CRT FACEPLATE SO
FULL LENGTH SLOT IS TOWARD THE TOP OF THE
INSTRUMENT.
SCREW IN THE
FOUR
CORNER
THUMBSCREWS.
Figure
3-1.
Removal
and
installation of
faceplate
filters.
3-2