AIR FORCE
T033A1-13-496-1
NAVELEX
0969-
LP-1 70-0010
Maintenance
Instructions
SECTION
V
MAINTENANCE
INSTRUCTIONS
5-1. OPERATIONAL
CHECKOUT.
The
operational
checkout
is a
covers-on
performance
test of the
AN/USM-
425(V)1
using test
equipment
listed in Table
2-1. Satis-
factory
completion
of the check out
procedures
indicates
that
the
instrument
should
perform
as
listed
in the
Char-
acteristics
columns of
Tables
1-1
through
1-3. Operational
checkout
procedures are
contained in
Table 5-1,
which is
further
explained as
follows:
a.
The
STEP
column lists
the sequential steps
of the
procedure.
b. The
PROCEDURE column lists
the instructions
and
illustrations
used
to
set up
and perform the
test(s).
c.
The
NORMAL
INDICATION column lists
the
result
that
the test
should produce.
d. The
control settings
listed
in step 1
are
used as initial
settings for
each numbered
procedure.
Therefore,
the
numbered
procedures may
be performed
in any
order
by
completing
step 1 and
step
2,
then
any other numbered
step.
This feature
is useful for
testing the instrument after
making
repairs or replacing
components.
Do not
connect the instrument to a power
source
until instructed
to
do
so
in a pro-
cedural step. This will prevent
instrument
damage in the event
the
LINE RANGE
Selector
has been improperly set.
Table
5-1. Operational
Checkout
Procedures
Step
Procedure
Normal
Indication
1.
Turn-on
Procedure.
a.
Set
instrument controls as
follows
(where
controls are
duplicated,
set both
the same):
POSITION (vertical)
Midrange
VOLTS/D IV
5 m
(1
X
probe
window)
VAR
(VOLTS/DIV)
Fully
clockwise (detent)
AC-GND-DC
DC
VERT MODE
CH 1
INVERT
Out
(normal)
INTEN
Midrange
SCALE
ILLUM
Fully
counterclockwise
HORIZ
DISPLAY
A
A AND
B
TIME/DIV
.1 ms
VAR
(A AND B
TIME/DIV
Fully clockwise
(detent)
DELAY
TIME POS
0.0
X10
MAG
Out
(off)
A
TRIGGER
HOLDOFF
NORM
(detent)
LEVEL
Midrange of
+
side of
control (ad-
just as
necessary
throughout
procedure)
SLOPE
OUT
+
COUPLING
AC
SOURCE
NORM
TRIG
MODE
AUTO
POSITION (horizontal)
Midrange
5-1