Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:ARINC429A:LABel:HIVALue <QString>
TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIV ALue?
Related Commands
TRIGger:A:BUS:B<x>:ARINC429A:CONDition
TRIGger:A:BUS:B
<x>:ARINC429A:LABel:QUALifier
TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue
Arguments
QString is a quoted string of 8 bits. The allowable characters are 0, 1, and X.
The bits specified in the quoted string replace the least significant bits, leaving
any unspecified upp
er bits unchanged.
Examples
TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIV ALue "XXXX1000" sets the
upper limit of the range to XXXX1000.
TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIV ALue? might return
"XXXXXXXX".
TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUALifier
This command specifies the qualifier to be used when triggering on the ARINC429
label field. The trigger condition must be set to LABel or LABELANDDATA.
The default qualifier is "Equal to". B<x> is the bus number.
Conditions
This command requires installation of a DPO4AERO application module for
MDO4000C models, or MDO3AERO for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUA Lifier
{LESSthan|MOREthan|Equal|UNEQual|LESSE Qual|MOREEQual|
INrange|OUTrange}
TRIGger:A:BUS:B<x>:ARINC429A:LABel:QUA Lifier?
Related Commands
TRIGger:A:BUS:B<x>:ARINC429A:CONDition
TRIGger:A:BUS:B<x>:ARINC429A:LABel:HIVALue
TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue
Arguments
LESSthan sets label qualifier to less than.
MOREthan sets the label qualifier to greater than.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-779