Acquiring and Displaying Waveforms
TDS 500D, TDS 600B, & TDS 700D User Manual
3–27
Choosing an Acquisition Mode
The TDS Oscilloscopes are digital products that can acquire and process your
input signal in a variety of modes. To help you choose the best mode to use for
your signal measurement task, this section first describes:
How the oscilloscope samples and digitizes an input signal
How the different acquisition modes (such as interpolation) affect this process
How to select among these modes
Following these descriptions are procedures for selecting the sampling and
acquisition modes, beginning with Checking the Acquisition Readout on page 3–35.
Acquisition is the process of sampling the analog input signal, digitizing it to
convert it into digital data, and assembling it into a waveform record. (See
Figure 3–11.) The oscilloscope creates a digital representation of the input signal
by sampling the voltage level of the signal at regular time intervals. The sampled
and digitized points are stored in memory along with corresponding timing
information. You can use this digital representation of the signal for display,
measurements, or further processing.
Input Signal Sampled Points Digital Values
+5.0 V
–5.0 V
+5.0 V
–5.0 V
0 V 0 V 0 V 0 V
Figure 3–11: Acquisition: Input Analog Signal, Sample, and Digitize
Sampling and Digitizing

Table of Contents

Other manuals for Tektronix TDS 700D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS 700D and is the answer not in the manual?

Tektronix TDS 700D Specifications

General IconGeneral
BrandTektronix
ModelTDS 700D
CategoryTest Equipment
LanguageEnglish

Related product manuals