EasyManuals Logo
Home>Toshiba>Inverter>TOSVERT VF-AS1 Series

Toshiba TOSVERT VF-AS1 Series User Manual

Toshiba TOSVERT VF-AS1 Series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
E6581581
- 14 -
3.2.4.2. FA06 (Command word 1)
bit Function 0 1 Note
0
Preset Speed
operation frequencies 1
1
Preset Speed operation
frequencies 2
2
Preset Speed operation
frequencies 3
3
Preset Speed operation
frequencies 4
Preset speed operation is disabled
or preset speed operation
frequencies (1-15) are set by
specifying bits for preset speed
operation frequencies 1-4.
(000: Preset speed operation OFF,
001-111: Setting of preset speed
operation frequencies (1-15))
-
4
Motor selection (1 or 2)
(THR 2 selection)
Motor 1
(THR1)
Motor 2
(THR2)
THR1: thr
THR2: f173
5 PI control Normal operation PI OFF -
6
Acceleration/decelerati
on pattern selection (1
or 2)
(AD2 selection)
Acceleration/dec
eleration pattern
1 (AD1)
Acceleration/dec
eleration pattern
2 (AD2)
AD1: acc, dec
AD2: f500, f501
7 DC braking OFF
Forced DC
braking
-
8 Jog OFF Jog run -
9 Forward/reverse Forward run Reverse run -
10 Run/stop Stop Run -
11 Coast stop command Standby Coast stop -
12 Emergency stop OFF Emergency stop Always enabled, ā€œEā€ trip
13 Fault reset OFF Reset
No data is returned from the
inverter
14
Frequency priority
selection
OFF Enabled
Enabled regardless of the setting of
fmod
15
Command priority
selection
OFF Enabled
Enabled regardless of the setting of
cmod
Note: Set 0 to reserved bit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS1 Series and is the answer not in the manual?

Toshiba TOSVERT VF-AS1 Series Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS1 Series
CategoryInverter
LanguageEnglish

Related product manuals