E6581581
- 39 -
5.1.5. Instance 22: CIP speed and torque control output
Instance 22 mapping
Word Number Definition
0 CIP basic command word
1 Speed setpoint (min
-1
)
2 Torque setpoint (Nm)
Assembly 22 output command
Refer to Assembly 20.
5.1.6. Instance 72: CIP speed and torque control input
Assembly 72 mapping
Word Number Definition
0 CIP basic status word
1 Actual speed (min
-1
)
2 Actual torque (Nm)
Assembly 72 input status
Refer to Assembly 70.
5.1.7. Instance 23: CIP extended speed and torque control output
Assembly 23 mapping
Word Number Definition
0 CIP extended command word
1 Speed setpoint (min
-1
)
2 Torque setpoint (Nm)
Assembly 23 output command
Refer to Assembly 21.
5.1.8. Instance 73: CIP extended speed and torque control input
Assembly 73 mapping
Word Number Definition
0 CIP extended status word
1 Actual speed (min
-1
)
2 Actual torque (Nm)
Assembly 73 input status
Refer to Assembly 71.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS1 Series and is the answer not in the manual?

Toshiba TOSVERT VF-AS1 Series Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS1 Series
CategoryInverter
LanguageEnglish

Related product manuals