EasyManuals Logo
Home>Toshiba>Inverter>TOSVERT VF-AS1 Series

Toshiba TOSVERT VF-AS1 Series User Manual

Toshiba TOSVERT VF-AS1 Series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
E6581581
- 8 -
Title
Communi
cation No.
Function Description
Default
setting
f822 0822
Actual Rate (L port)
f823 0823
Actual Rate (R port)
This field displays the baud rate and the transmission
mode currently used by the communication card.
(Display only)
0:unconnected
1:10Mbps Full
2:10Mbps Half
3:100Mbps Full
4:100Mbps Half
-
f824 0824 Services
Enables web server and e-mail server *
*Not used for this version. (Reserved)
0
f831-
f838
0831-
0838
IOScanner
Command data
0: No action
1: FA06 (Communication option command 1)
2: FA23 (Communication option command 2)
3: FA07 (Frequency command, 0.01Hz)
4: FA33 (Torque command, 0.01%)
5: FA50 (Terminal output)
6: FA51 (Analog output (FM) data from comm.)
7: FA52 (Analog output (AM) data from comm.)
8: F601 (Stall prevention level, %)
9: F441 (Power running torque limit 1 level, 0.01%)
10: F443 (Regenerative braking torque limit 1 level,
0.01%)
11: F460 (Speed loop proportional gain)
12: F461 (Speed loop stabilization coefficient)
0
f841-
f848
0841-
0848
IOScanner
Monitor data
0: No action
1: FD01 (Inverter status 1)
2: FD00 (Output frequency, 0.01Hz)
3: FD03 (Output current, 0.01%)
4: FD05 (Output voltage, 0.01%)
5: FC91 (Inverter alarm)
6: FD22 (PID feedback value, 0.01Hz)
7: FD06 (Input terminal status)
8: FD07 (Output terminal status)
9: FE36 (VI/II input)
10: FE35 (RR/S4 input)
11: FE37 (RX input)
12: FD04 (Input voltage (DC detection), 0.01%)
13: FD16 (Speed feedback (real-time value)
14: FD18 (Torque, 0.01%)
15: FE60 (My monitor)
16: FE61 (My monitor)
17: FE62 (My monitor)
18: FE63 (My monitor)
19: F880 (Free notes)
20: FD29 (Input power, 0.01kW)
21: FD30 (Output power, 0.01kW)
22: FE14 (Cumulative operation time, 0.01=1 hour)
23: FE40 (FM terminal output monitor)
24: FE41 (AM terminal output monitor)
0
f849 0849
Communication2 time-out
condition selection
0: Disconnection detection
1: When communication mode enable
2: 1+Driving operation
0
 0850
Disconnection detection
extended time
0.0~100.0 sec.
0.0
f851 0851
Operation
at communication error
by disconnection
0: Inverter stop, communication command, frequency
mode open (by cmod, fmod)
1: None (continued operation)
2: Deceleration stop
3: Coast stop
4: Network error (err8 trip)
5: Preset speed operation (by f852 setting)
0
f852 0852
Preset speed operation
selection
0:None
1~15:Preset speed operation (by parameter setting)
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS1 Series and is the answer not in the manual?

Toshiba TOSVERT VF-AS1 Series Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS1 Series
CategoryInverter
LanguageEnglish

Related product manuals